[1]郭 强,祝清杰.光伏供电油气回收中直流无刷压缩机控制实现及性能分析[J].常州大学学报(自然科学版),2013,(01):46-50.[doi:10.3969/j.issn.2095-0411.2013.01.010]
 GUO Qiang,ZHU Qing-jie.Achievable Control and Performance Analysis of DC Brushless Compressor Motor in Oil and Gas Recovery of Photovoltaic System[J].Journal of Changzhou University(Natural Science Edition),2013,(01):46-50.[doi:10.3969/j.issn.2095-0411.2013.01.010]
点击复制

光伏供电油气回收中直流无刷压缩机控制实现及性能分析()
分享到:

常州大学学报(自然科学版)[ISSN:2095-0411/CN:32-1822/N]

卷:
期数:
2013年01期
页码:
46-50
栏目:
出版日期:
2013-01-01

文章信息/Info

Title:
Achievable Control and Performance Analysis of DC Brushless Compressor Motor in Oil and Gas Recovery of Photovoltaic System
作者:
郭 强祝清杰
常州大学 石油工程学院,江苏 常州 213016
Author(s):
GUO QiangZHU Qing-jie
School of Petroleum Engineering,Changzhou University,Changzhou 213016,China
关键词:
油气回收 光伏直流供电 直流无刷压缩机 电机控制 性能分析
Keywords:
oil and gas recovery photovoltaic DC power supply DC brushless compressor motor control performance analysis
分类号:
TK 9
DOI:
10.3969/j.issn.2095-0411.2013.01.010
文献标志码:
A
摘要:
所开发的油气回收系统样机采用了“冷凝+吸附”的油气回收方式。冷凝段制冷压缩机装配了直流无刷电机。整个系统依靠太阳能光伏直流供电。介绍了压缩机的供电系统,阐述了实现冷凝段直流无刷压缩机电机的反电动势检测、位置切换和软启动的原理和方法。通过监测直流无刷压缩机启动、运行的过程,总结并分析了压缩机在太阳能光伏直流供电状态下性能参数的变化规律,得到了压缩机制冷量、输入功率以及COP随冷凝蒸发温度的变化曲线,得出了在实验工况下样机COP值最高达4.51和相对于交流供电节能20%的结论。
Abstract:
The oil and gas recovery prototype is developed by using“condensation+adsorption” recovery mode. Condensation section of refrigeration compressor assembled DC brushless motor. The whole system relied on solar photovoltaic DC power supply. This paper is to introduce the power supply system ofthe compressor, and to describe the back-EMF detection, position switches, and the principle and processes of soft start-up of DC brushless compressor motor incondensation section. Through monitoring start-up and operation processes of theDC brushless compressor, the changes of performance parameters of the compressor in solar photovoltaic DC power supply are summarized and analyzed, and then the compressor refrigerating capacity, input power and COP changing curve along with the condensing evaporating temperature is obtained. Finally, the conclusion of the highest COP value 4.51 of prototype under the experimental condition andsaving energy 20% relative to AC power supply is reached.

参考文献/References:

[1]刘静,李自力,孙云峰,等.国内外油气回收技术的研究进展[J].油气储运,2010,29(10):726-743.
[2]孟懿.太阳能光伏发电的发展[J].东北电力技术,2010,31(11):19-21.
[3]肖本贤.小功率低成本的无刷直流电机控制器研制[J].机电工程,2000,17(1):47-52.
[4]黄维秋,彭群,刘君.加油站油气排放治理技术[J].环境工程学报,2009,3(2):327-330.
[5]黄维秋,蔡智,赵书华,等.油气吸收回收系统的研究及工业应用——(Ⅰ)中型试验及结果分析[J].石油炼制与化工,2006,37(8):49-53.
[6]蔡智,黄维秋,赵书华,等.油气吸收回收系统的研究及工业应用——(Ⅱ)工业试验及效果分析[J].石油炼制与化工,2006,37(9):41-44.
[7]黄跃进,徐鸣,沈希,等.基于直流变频技术的压缩机控制器设计[J].压缩机技术,2005(5):20-23.
[8]王永.“反电势法”无刷直流电机控制系统研究[D].南京:东南大学,2004.
[9]张智伟.冰箱压缩机高压无刷直流电机及控制系统研究[D].武汉:湖北工业大学,2007.
[10]周托.无位置传感器无刷直流电机控制系统的设计与研究[D].西安:西北工业大学,2006.
[11]张小鸣,龙仕玉.基于DSP他励直流电机模糊PID控制器仿真研究[J].常州大学学报:自然科学版,2012,24(1):82-85.
[12]徐凯.浅谈电动机软启动技术[J].中国新技术新产品,2011(7):145-146.
[13]石日祥,荣连春,石晓波,等.变频冰箱压缩机用无刷直流电机的研制[J].电机电器技术,2003(4):7-11.

相似文献/References:

[1]蔡道飞,黄维秋,张 琳,等.微波加热再生活性炭的实验研究[J].常州大学学报(自然科学版),2013,(03):37.[doi:10.3969/j.issn.2095-0411.2013.03.010]
 CAI Dao fei,HUANG Wei qiu,ZHANG Lin,et al.Experimental Research on Regeneration of Activated Carbon by Microwave Heating[J].Journal of Changzhou University(Natural Science Edition),2013,(01):37.[doi:10.3969/j.issn.2095-0411.2013.03.010]

备注/Memo

备注/Memo:
基金项目:江苏省科技计划项目(SBE201170094) 作者简介:郭强(1967-),山西代县人,副教授,硕士生导师,研究方向为新能源的开发与利用。
更新日期/Last Update: 2013-01-01