[1]何 振,陈 琪,李洪杰.变频输油泵机组节能监测微温差测试方法[J].常州大学学报(自然科学版),2013,(02):48-50.[doi:10.3969/j.issn.2095-0411.2013.02.012]
 HE Zhen,CHEN Qi,LI Hong jie.Micro Temperature Difference Method of Frequency Conversion Oil Pump Units[J].Journal of Changzhou University(Natural Science Edition),2013,(02):48-50.[doi:10.3969/j.issn.2095-0411.2013.02.012]
点击复制

变频输油泵机组节能监测微温差测试方法()
分享到:

常州大学学报(自然科学版)[ISSN:2095-0411/CN:32-1822/N]

卷:
期数:
2013年02期
页码:
48-50
栏目:
出版日期:
2013-03-30

文章信息/Info

Title:
Micro Temperature Difference Method of Frequency Conversion Oil Pump Units
作者:
何 振陈 琪李洪杰
中国石化集团管道储运公司 华东管道设计研究院,江苏 徐州 221008
Author(s):
HE ZhenCHEN QiLI Hong jie
East China Pipeline Design & Research Institute,SINOPEC Pipeline Transport & Storage Company,Xuzhou 221008,China
关键词:
变频技术 节能监测 效率
Keywords:
frequency conversion technology energy saving monitors efficiency
分类号:
TE 866
DOI:
10.3969/j.issn.2095-0411.2013.02.012
文献标志码:
A
摘要:
在原油和成品油输油管线上变频输油泵的使用消除泵管压差而产生的节流损失,降低了输油能耗,节约了电能,改善了工艺。因此有必要对变频输油泵机组的效率进行计算,但是在变频输油泵现场测试过程中电动机输出功率受现场影响无法直接测得,通常采用比例定律计算,但是误差较大。而微温差法很好的解决了这个问题,该方法以热力学能量守恒和转换原理为基础,克服了比例定律的局限性,根据焓是状态参数的特性计算变频输油泵机组的效率。现场测试表明,通过这个方法结合并必要的测试参数,能够快速、准确计算变频输油泵机组的能效。
Abstract:
Using frequency conversion oil transfer pump in pipelineof crude oil and refined oil can eliminate the energy saving damage caused by pump pipe depression differences,reduce the energy consumption,save electric energy and improve the process.Therefore,it is necessary to calculate the efficiencyof frequency conversion oil pump units.However,the motor output power of frequency conversion oil pump influenced by scene conditions is unable to be tested,which can be calculated by the law of proportionality with large error.The problemcan be solved by micro temperature difference method.This method is based on the law of energy conservation and energy conversion of thermodynamics,which overcome the limitations of the law of proportionality according to the characteristics of enthalpy as a state parameter to calculate efficiency of frequency conversion oil pump units.The field test showed that the efficiency of frequency conversion oil pump units could be calculated rapidly and accurately by this method togeter with the necessary test parameters.

参考文献/References:

[1]李宝山.输油泵采用变速与节流调节效率的探讨[J].油气储运,1995,14(2):55-60.
[2]朱复中.泵特性的微温差法测试技术研究[J].华东化工学院学报,1985,11(2):177-184.
[3]沈维道,蒋智敏,童钧耕.工程热力学[M].北京:高等教育出版社,2001:33.
[4]国家技术监督局.GB/T 16666-1996 泵类及液体输送系统节能监测方法[S].北京:中国标准出版社,1996.
[5]国家标准化委员会.GB/T 1032-2005 三相异步电动机实验方法[S].北京:中国标准出版社,2005.
[6]刘梦军,王振国,陈雨生,等.泵机组液体输送系统的节能监测与计算[J].资源节约与环保,2009(4):43.
[7]冯金泉,蒋式柏.微温差法泵特性测试的精度及其影响因素[J].华东电力,1984(10):22-24.

备注/Memo

备注/Memo:
作者简介:何振(1980-),男,江苏徐州人,工程师。