[1]黄士君.输电铁塔受腐蚀节点蚀余力学性能的有限元分析[J].常州大学学报(自然科学版),2015,(03):35-38.[doi:10.3969/j.issn.2095-0411.2015.03.007]
 HUANG Shijun.The Finite Element Analysis of Corrosion-Joint Mechanical Properties in Steel Transmission Towers[J].Journal of Changzhou University(Natural Science Edition),2015,(03):35-38.[doi:10.3969/j.issn.2095-0411.2015.03.007]
点击复制

输电铁塔受腐蚀节点蚀余力学性能的有限元分析()
分享到:

常州大学学报(自然科学版)[ISSN:2095-0411/CN:32-1822/N]

卷:
期数:
2015年03期
页码:
35-38
栏目:
出版日期:
2015-07-25

文章信息/Info

Title:
The Finite Element Analysis of Corrosion-Joint Mechanical Properties in Steel Transmission Towers
作者:
黄士君
江苏省电力公司 电力经济技术研究院,江苏 南京 210008
Author(s):
HUANG Shijun
Economic Research Institute, Jiangsu Electric Power Company, Nanjing 210008,China
关键词:
输电铁塔大气腐蚀节点损伤蚀余力学性能有限元模型
Keywords:
steel transmission towers atmospheric corrosion remaining mechanical properties finite element model
分类号:
TM 753
DOI:
10.3969/j.issn.2095-0411.2015.03.007
文献标志码:
A
摘要:
输电线路铁塔结构,由于直接暴露在大气环境中,极易因大气污染物、恶劣环境的作用而受到腐蚀,导致构件有效钢材厚度降低。对于受削弱铁塔构件力学性能的研究,目前尚显不足。本研究结合实际工程,对受到不同程度腐蚀的输电铁塔节点结构,建立有限元模型进行数值模拟计算,得到其刚度、强度的折减率。研究表明在节点锈蚀厚度不超过0.2〖KG3x〗mm、构件锈蚀厚度不超过1〖KG3x〗mm的条件下,输电线路铁塔结构可以继续使用,本研究可为同类实际工程提供参考。
Abstract:
Steel transmission towers, which are exposed to atmosphere, are easily to be corroded. However researches on the mechanical properties caused by corrosion were rarely reported. This paper presents a numerical analysis on strength and stiffness reduction rate of a corroded steel joint in steel transmission towers. The research showed that given the node corrosion thickness is less than 0.2〖KG3x〗mm, the thickness of the corrosion of components is less than 1〖KG3x〗mm, the steel transmission tower structure can be kept for further use. The research provided reference for similar engineering.