[1]涂保华,钱伟,陈兆林,等.城市污水处理系统中抗生素类污染物去除的优化试验研究[J].常州大学学报(自然科学版),2015,(04):91-95.[doi:10.3969/j.issn.2095-0411.2015.04.017]
 TU Baohua,QIAN Wei,CHEN Zhaolin,et al.Experimental Study on the Optimization of Urban Sewage Treatment System to Remove Antibiotic Pollutants[J].Journal of Changzhou University(Natural Science Edition),2015,(04):91-95.[doi:10.3969/j.issn.2095-0411.2015.04.017]
点击复制

城市污水处理系统中抗生素类污染物去除的优化试验研究()
分享到:

常州大学学报(自然科学版)[ISSN:2095-0411/CN:32-1822/N]

卷:
期数:
2015年04期
页码:
91-95
栏目:
环境科学与工程
出版日期:
2015-11-15

文章信息/Info

Title:
Experimental Study on the Optimization of Urban Sewage Treatment System to Remove Antibiotic Pollutants
作者:
涂保华1钱伟1陈兆林2张晟1储云1董良飞1
1. 常州大学 环境与安全工程学院,江苏 常州 213164; 2. 北京国环清华环境工程设计研究院有限公司,北京100084
Author(s):
TU Baohua1QIAN Wei1CHEN Zhaolin2ZHANG Sheng1CHU Yun1DONG Liangfei1
1. School of Environmental and Safety Engineering,Changzhou University,Changzhou 213164,China; 2. Beijing Guohuan Tsinghua Environmental Engineering Design & Research Institute,Beijing 100084,China
关键词:
SBR 抗生素类污染物 HRT SRT 曝气量
Keywords:
SBR antibiotic pollutant HRT SRT amount of aeration
分类号:
X 703
DOI:
10.3969/j.issn.2095-0411.2015.04.017
文献标志码:
A
摘要:
以常州市某城市污水处理厂中罗红霉素、磺胺甲恶唑、诺氟沙星和四环素为目标,在现场调查的基础上搭建模拟SBR与高级氧化联用装置研究抗生素污染物的优化去除,分析了抗生素污染物去除效果的影响因素。实验结果表明:城市污水处理系统中,罗红霉素、磺胺甲恶唑、诺氟沙星和四环素的初步去除率分别为36%、6%、52%和77%,优化之后去除率分别为84%、75%、79%和93%。SRT、HRT、pH、曝气量和高级氧化法技术对抗生素污染物的去除有一定影响,同种抗生素污染物去除因不同因素而异,同一个因素影响的程度因抗生素种类而异。
Abstract:
Based on the treatment of Roxithromycin, sulfamethoxazole, tetracycline and Norfloxacin in a certain sewage treatment plant in Changzhou, a stimulation SBR and advanced oxidation coupling device were built on the basis of field investigation for the optimazation of removal of antibiotic pollutants. The factors that influence the removal of antibiotic pollutants were analysed. The Experimental results show that the preliminary removal rate of Roxithromycin, sulfamethoxazole, tetracycline and Norfloxacin is 36%,6%,52% and 77% respectively in the City sewage treatment system.And the removal rate was 84%,75%,79% and 93% respectwely after optimization. SRT,HRT, pH,aeration and advanced oxidation technology have influence on the removal of antibiotic pollutants.The same kind of the removal of antibiotic pollutants have different results due to different factors; beause of the types of antibiotics the degree of influence of the same factor have differences.

参考文献/References:

[1]徐维海,张干,邹世春,等.典型抗生素类药物在城市污水处理厂中的含量水平及其行为特征[J].环境科学,2007, 28(8):1779-1783.
[2]邵一如,席北斗,曹金玲,等.抗生素在城市污水处理系统中的分布及去除[J].环境科学与技术,2013,7(7):85-92.
[3]肖斌,黄满红,陈亮.活性污泥SBR系统对四环素耐药菌和总四环素的去除特性[J].环境化学,2012,12(5):1974-1978.
[4]孙丰霞.污水处理系统中磺胺嘧啶和磺胺甲噁唑的优化处理研究[D]. 泰安:山东农业大学,2014:63-71.
[5]杨程,郭劲松.污泥龄对活性污泥处理微量磺胺类药物的影响[J].重庆大学学报,2012,6(4):63-71.
[6]刘冲,黄满红,肖斌.城市污水厂中四环素类抗生素分布特性研究[J].广州化工,2012,4(3):153-156.
[7]李慧. 四环素类抗生素(TC)在活性污泥处理系统中的去除行为研究[D]. 泰安:山东农业大学,2013:119-121.
[8]殷小伟,强志民,贲伟伟,等.污水厂不同生物处理工艺对抗生素的去除效果[J].中国给水排水,2012,22(3):22-26.
[9]阿丹,杨扬,戴玉女,等.自然曝气生物滤床对二级污水处理厂尾水中抗生素的去除效果及影响因素研究[J].生态科学,2012,3(2):289-294.