[1]夏 雄,徐 璜,王小平,等.Φ500空心管桩受弯特性分析[J].常州大学学报(自然科学版),2014,(01):84-88.[doi:10.3969/j.issn.2095-0411.2014.01.019]
 XIA Xiong,XU Huang,WANG Xiao-ping,et al.Study on flexural behaviors of PHC pile of 500mm outer diameter[J].Journal of Changzhou University(Natural Science Edition),2014,(01):84-88.[doi:10.3969/j.issn.2095-0411.2014.01.019]
点击复制

Φ500空心管桩受弯特性分析()
分享到:

常州大学学报(自然科学版)[ISSN:2095-0411/CN:32-1822/N]

卷:
期数:
2014年01期
页码:
84-88
栏目:
安全工程
出版日期:
2014-02-28

文章信息/Info

Title:
Study on flexural behaviors of PHC pile of 500mm outer diameter
作者:
夏 雄1 徐 璜1 王小平1 徐汉东2 奚赛英3
1. 常州大学 环境与安全工程学院,江苏 常州 213164; 2.江苏鼎达建筑新技术有限公司,江苏 常州 213015; 3.常州市规划设计院,江苏 常州 213003
Author(s):
XIA Xiong1XU Huang1WANG Xiao-ping1XU Han-dong2XI Sai-ying3
1. School of Environment and Safety Engineering,Changzhou University,Changzhou 213164,China; 2.Jiangsu Dinda Construction and New Technology Corporation,Changzhou 213015,China; 3.Changzhou City Planning and Design Institute, Changzhou 213003,China
关键词:
空心管桩 承台 受弯特性 参数优化 ANSYS
Keywords:
PHC flexural behaviors parameter optimization ANSYS
分类号:
TU473.1
DOI:
10.3969/j.issn.2095-0411.2014.01.019
文献标志码:
A
摘要:
预应力混凝土空心管桩由于有效截面积小,受弯特性常成为控制因素。长三角地区常采用Φ500空心管桩作为工程设计桩体。在桩土共同作用分析的基础上,采用有限元软件ANSYS对不同参数条件下的单根管桩模拟,探讨管桩壁厚、有效面积、水平荷载、弯矩、约束条件以及桩身弹性模量等工程参数对管桩受弯工作性状的影响。研究表明,管桩弯矩和剪力影响范围主要集中在地面以下1~3 m范围内。随着推力和轴力的增加,桩身水平位移、中桩剪力和角桩剪力都将增大,角桩影响更为显著; 优化管桩截面面积应该选取为0.170 m2,管桩壁厚应选取160 mm。
Abstract:
Because of the smaller crosssectional area, the flexural properties often become the controlling factor in PHC pile. Φ500 PHC is widely used as an engineering design pile in the Yangtze River Delta region. On the basis of the analysis of pile soil interaction mechanism, the single Pile under different conditions is discussed. The parameters are discussed in this article are PHC pile's wall thickness, horizontal loads, bending moments, pile elastic modulus and other engineering parameters. The studies show that, the distribution of bending moment and shear is significant in 1~3 m below the top surface of the pile.Optimize sectional area of Φ500 PHC should be selected as 0.17, and the wall thickness should be selected as 160 mm.

参考文献/References:

[1]苑辉.谈预应力混凝土空心方桩较管桩性能的优越性[J].山西建筑,2010,36(22):101-102.
[2] Dyson G J,RandolPh M F.Monotonic lateral loading of Piles in calcareous sand[J].Joural of Geotechnical and Geo environmental Engineering,ASCE,2001,127(4):346-352.
[3]施峰.PHc管桩荷载传递的试验研究[J].岩土工程学报,2004,26(1):95-99.
[4]王钰,林军,陈锦剑.软土地基中PHC管桩水平受荷性状的试验研究[J].岩土力学,2005,26(增):39-42.
[5]施松华.高强度预应力混凝土管桩承载性能的分析研究[D].南京:河海大学,2007.
[6]刘汉龙,张建伟,彭劫.PCC桩水平承载特性足尺模型试验研究[J].岩土工程学报,2009,31(2):161-165.
[7]何筱进.现浇混凝土薄壁管桩水平承载性状试验研究[D].南京:河海大学,2004:4-5.
[8]王继成.单桩承台对桩水平承载力的影响研究[D].杭州:浙江工业大学,2007:26-36.
[9]夏雄,董亮亮,张爱琴,等.考虑气相堵塞的土样渗透试验分析[J].常州大学学报:自然科学版,2012,24(1):55-58.
[10]中华人民共和国交通部.JTS 167-4-2012港口工程桩基规范[S].北京:人民交通出版社,2012.

备注/Memo

备注/Memo:
基金项目:常州市科技局研究基金(CE20135038); 江苏鼎达应用研究基金(KYH1202162) 作者简介:夏雄(1972-),男,四川成都人,博士,副教授; 通讯联系人:徐璜。
更新日期/Last Update: 2014-02-20