[1]陈春红,朱平华,陈世洲.隧道火灾下气凝胶复合混凝土强度经时变化[J].常州大学学报(自然科学版),2020,32(03):86-92.[doi:10.3969/j.issn.2095-0411.2020.03.012]
 CHEN Chunhong,ZHU Pinghua,CHEN Shizhou.Study on Strength Variation of Aerogel Composite Concrete Exposed to Tunnel Fire[J].Journal of Changzhou University(Natural Science Edition),2020,32(03):86-92.[doi:10.3969/j.issn.2095-0411.2020.03.012]
点击复制

隧道火灾下气凝胶复合混凝土强度经时变化()
分享到:

常州大学学报(自然科学版)[ISSN:2095-0411/CN:32-1822/N]

卷:
第32卷
期数:
2020年03期
页码:
86-92
栏目:
土木工程
出版日期:
2020-05-28

文章信息/Info

Title:
Study on Strength Variation of Aerogel Composite Concrete Exposed to Tunnel Fire
文章编号:
2095-0411(2020)03-0086-07
作者:
陈春红 朱平华 陈世洲
(常州大学 环境与安全工程学院, 江苏 常州 213164)
Author(s):
CHEN Chunhong ZHU Pinghua CHEN Shizhou
(School of Environmental & Safety Engineering, Changzhou University, Changzhou 213164, China)
关键词:
隧道火灾 气凝胶砂浆涂层 自密实混凝土 强度退化 冷却方式
Keywords:
tunnel fire aerogel mortar coating self-compacting concrete compressive strength degradation cooling method
分类号:
TU 502
DOI:
10.3969/j.issn.2095-0411.2020.03.012
文献标志码:
A
摘要:
为了分析气凝胶砂浆对隧道混凝土的防火隔热效果,研究了隧道火灾下气凝胶复合混凝土强度随时间退化的规律。首先在气凝胶体积掺量为骨料体积的60%条件下制备出具有防火涂层潜力的砂浆,涂覆在自密实高性能混凝土试件上制成气凝胶复合混凝土,按Eurocodes HC曲线升温(10 min达到800 ℃,30 min达到1 200 ℃)对试件进行受火试验,选取8个受火时间和两种冷却方式。结果表明:受火不超过2 h,气凝胶砂浆对试件的保护效果较好,受火2 h后气凝胶砂浆对试件的防火隔热效果开始减弱。自然冷却方式下,相同受火时间时复合试件比未涂敷涂层的试件的剩余强度最高可达2.07倍; 喷淋冷却下,相同受火时间时复合试件比未涂敷涂层的试件的剩余强度最高可达2.89倍。冷却方式对试件受火后的强度退化也有明显影响。受火时间相同时,自然冷却后的剩余强度比喷淋冷却后的高,受火2 h时高了约75%。
Abstract:
In order to analyze the effect of aerogel mortar on fire insulation of tunnel concrete, the law of strength degradation of aerogel composite concrete with duration time in tunnel fire was studied. Firstly, a mortar having the potential of fireproof coating was prepared,and the aerogel volume was 60% of the aggregate volume. The mortar was used as insulation layer and coated on the surface of self-compacting concrete. Thus aerogel composite concrete was made. According to Eurocodes HC curve(800 ℃ in 10 min, 1 200 ℃ in 30 min), the specimens were subjected to fire test. 8 fire duration and two cooling modes were selected in this test. The results show that when exposed to fire for less than 2 hours, the protective effect of aerogel mortar on specimens was obvious, and it began to weaken after 2 hours. Under natural cooling, the residual strength of specimen coated aerogel mortar at the same duration time was 2.07 times higher than that of uncoated specimen. Under spray cooling, the residual strength of specimen coated aerogel mortar could reach 2.89 times higher than that of uncoated specimen. The cooling mode also had an obvious effect on the strength degradation of the specimen. Residual strength of specimen with natural cooling was about 75% higher than that with spray cooling at the same duration time.

参考文献/References:

[1]《中国公路学报》编辑部. 中国隧道工程学术研究综述[J]. 中国公路学报,2015,28(5):1-65.
[2]SHY B. Overview of traffic safety aspects and design road tunnels[J]. IATSS Research,2016,40(1):35-46.
[3]蒋树屏. 中国公路隧道数据统计[J]. 隧道建设, 2017, 37(5):643-644.
[4]公伟, 胡克旭. 自密实混凝土结构抗火研究进展[J]. 建筑结构学报,2016,37(3):1-9.
[5]李海艳, 刘刚. 高强混凝土高温性能研究进展[J]. 石家庄铁道大学学报(自然科学版),2016,29(1):48-54.
[6]王明年, 田源, 于丽, 等. 火灾下隧道混凝土高温损伤现场试验研究[J]. 消防科学与技术, 2019(8):1070-1074.
[7]朱平华, 于树奇, 刘文影, 等. 高性能混凝土抗隧道火灾爆裂剥落研究现状综述[J]. 混凝土,2018(7):24-29.
[8]孙厚超, 刘晶, 杨建明. 隧道防火涂料研究综述[J]. 安徽建筑, 2019(10): 196-197.
[9]郭晓煜, 张光磊, 赵霄. 气凝胶在建筑节能领域的应用形式与效果[J]. 硅酸盐通报,2015,34(2):444-449.
[10]张志华, 王文琴, 祖国庆, 等. SiO2气凝胶材料的制备、性能及其低温保温隔热应用[J]. 航空材料学报,2015,35(1):87-96.
[11]夏群, 徐晓岩, 朱平华. 气凝胶复合SCC隧道火灾剥落与强度退化研究[J]. 常州大学学报(自然科学版),2017,29(6):63-68,96.
[12]徐海珣. 硅基复合气凝胶的制备及其应用基础研究[D]. 大连:大连理工大学,2011.
[13]朱合华, 闫治国, 梁利, 等. 不同火灾升温曲线下隧道内温度场分布规律研究[J]. 地下空间与工程学报,2012(1):1595-1600.
[14]白振鹏, 李炎锋, 张鹏, 等. 隧道火灾温度分布的多元回归预测分析[J]. 消防科学与技术, 2018, 37(10):1304-1306, 1323.
[15]张士兵, 王心刚, 宋占辉. 运营隧道衬砌结构火灾损伤技术状况检测与评价[J]. 公路交通科技(应用技术版),2013(7):50-54.

相似文献/References:

[1]夏 群,徐晓岩,朱平华.气凝胶复合SCC隧道火灾剥落与强度退化研究[J].常州大学学报(自然科学版),2017,(06):63.[doi:10.3969/j.issn.2095-0411.2017.06.009]
 XIA Qun,XU Xiaoyan,ZHU Pinghua.Spalling and Strength Degradation of Aerogel Mortar Protected Self-Compacting Concrete Exposed to Tunnel Fire[J].Journal of Changzhou University(Natural Science Edition),2017,(03):63.[doi:10.3969/j.issn.2095-0411.2017.06.009]

备注/Memo

备注/Memo:
收稿日期:2019-10-15。
基金项目:国家自然科学基金资助项目(51678080,51678081)。
作者简介:陈春红(1983—),女,江西吉安人,硕士,讲师。E-mail:chench@cczu.edu.cn
引用本文:陈春红,朱平华,陈世洲. 隧道火灾下气凝胶复合混凝土强度经时变化[J]. 常州大学学报(自然科学版),2020,32(3):86-92.
更新日期/Last Update: 2020-06-11